Low Temperature Chamber – LTC – LN2 – 31m<sup>3</sup> – (1,100ft<sup>3</sup>)
Low Temperature Chamber – LTC – LN2 – 31m<sup>3</sup> – (1,100ft<sup>3</sup>)

Low Temperature Chamber – LTC – LN2 – 31m3 – (1,100ft3)

Climatic chamber 31m3 (1,100ft3) Hot Cold

-185°C / +200°C

 

Industries

Electronics and space industry.  

Application

Thermal tests on TX and RX antennas

Description

Unit composed of :
  • The test chamber
  • The machinery on the rear with its electrical cabinet
  • Drying and re-oxygenation features
  • Control and supervision by SPIRALE Vs software
 

Technical Data

Performances are given for :
  • An ambient temperature between +15°C and +35°C
  • A load of 500 kg
  • A dissipation of 500 W
  Temperature
  • Temperature range : -185°C to +200°C
  • Cooling rate : average 2°C/min, with the load, up to 10°C/mn with a load of 20kg
  • Heating rate : average 2°C/min, with the load, up to 10°C/mn with a load of 20kg
  • Temperature stability : ≤ ± 1,5°C Temperature homogeneity : ± 2,5°C at 20 cm of the walls.
(Compliant with IEC 60068-3-5/2001, § 4.5.2)  
Test  space  dimensions :
WxDxH : 3000mm x 3500mm x 3000mm (118.1” x 137.8” x 118.1”)