Search
Close this search box.

ZKB 10/6 MFA – ZKB 15/10 MFA

Specifications

Weiss has developed the ZKB 10/6 MF and 15/10 MFA tent air conditioning units in a dual design to be used for NBC protection and Colpro systems. The units can be used as a recirculating system. The cooling capacity is 11 kW and the heating capacity is 7.2 kW. The units come with option to be expandable with fuel powered heating.

Product Features

  • Split design
  • Cleanroom 1b approval with HEPA filter box as option
  • Use in COLPRO systems possible for ABC protection
  • Installation as a complete system (all modules outside the tent) or a split-system (evaporator module inside the tent) possible
  • Operation as a fresh air or a recirculating air system possible
  • Connection finished system integrates a fully hermetic refrigerant circuit with a scroll compressor (condenser module) and an airflow section with filter, cooler and supply fan (evaporator module)
  • Safe operation at external temperatures down to -32°C with fuel-powered heating (30 kW); no CO measurement required
  • Reliable operation at external temperatures of up to +58°C
  • Multi-stage air filtration possible

Operation modes

  • Cooling/heating (electrical) or only blowing without temperature
  • control or heating with optional heating module

Standard Version

  • Condenser and evaporator module
  • Installation as a complete system (all modules outside the tent) or a split-system (evaporator module inside the tent) possible
  • Operation as a fresh air or a recirculating air system possible
  • Compact construction with an additional transport frame
  • Design with aluminum panels, colored RAL 6031
  • Easy transport with integrated handles
  • Easy maintenance via big and easy removable covers
  • Connection finished system integrates a fully hermetic refrigerant circuit with a scroll compressor (condenser module) and an airflow section with filter, cooler and supply fan (evaporator module)
  • Evaporator module pre-installed with glycolheater and couplings to operate with optional heating module
  • Compressor equipped with soft starter (only ZKB 10/6 MFA)
  • Condenser and evaporator module connected by flexible hoses with quick release selfsealing couplings, length of 5 m
  • Integrated rotary field watchdog with a manual switch (only ZKB 15/10 MFA)
  • Control panel with switches, lamps, thermostat with cable (10 m) and plug to place inside the tent
  • Power connection cable (15 m) with plug
  • Special condensate drain system with flexible pipe, length of 5 m
  • Condenser fan speed controlled
  • Integrated lightning protection installed
  • Easy connection to an air distribution system (inside the tent) possible
  • Frame with wheels, to install at the existing transport frame at the modules
  • Electric heater, installed in the evaporator module to compensate the temperature difference between night and day
  • Separate heating module as a fuel heater (Diesel) with complete water-glycol circuit with pump, fuel lance for 20 l jerry cane, waste gas pipe and glycolhoses with quick release self seating couplings, 5 m long.
  • Air inlet filter G3 (metal, cleanable), integrated in the evaporator module
  • Air inlet filter F5 or F7, integrated in the evaporator module
  • Sand protection housing or sand filter to be installed at the evaporator module (placed outside the tent)
  • Supply air hose system (evaporator module outside the tent)
  • External insulated flexible air hose, length of 4.5 m colored black (other length possible)
  • Air hose connector to be installed at the evaporator module
  • Air distribution system (inside the tent)
  • Air hose system of Trevira CS, designed to be installed inside the tent
  • Air hose connector for connection on top of the evaporator module
  • Additional parts
  • Softstarter for compressor
  • Earthing kit
  • Tool to connect cooling pipes