Test Standard

Test Standard Description

Weiss Technik Chamber Solution

2006/42/EC

CE Compliant, CE Certified

AHAM HRF

American Home Appliance Testing AHAM

ASTM B117-97

ASTM B117

ASTM D5116 VOC – materials/products

ASTM D5116

BMW PR303.5

BMW PR303.5 climate test trim parts

WWH

BMW PR306.5

BMW PR306.5 solar test trim parts

WWH

BMW PR308.2

BMW PR308.2 test bonded joints

WWH

DIN 75 220

Ageing Automobile Components in Solar Simulation Units

EN 60204-1:2006/AC: 2010

CE Compliant, CE Certified

EN 61010-1

CE Compliant, CE Certified

GMW14319, Temperature Cycle Profile for Vibration

GMW14319

EV

GMW14785 PVT Cycle Test

GMW14785 pressure vibration test

EV

GMW3172 Electrical Component Testing

GMW3172 electronic testing

EVH

IEC 60068-2-14, Test Na2

IEC 60068-2-14

ISO 12097-2

ISO 12097-2 Road Vehicles – Airbag Modules

ISO 12219-1 VOC-Whole vehicle

ISO 12219-1 VOC

WW

ISO 12219-4 VOC-Small chamber method

ISO 12219-4 VOC-Small chamber method

ISTA Series

ISTA Packaging Testing

WPH / WWH / ENDH / EV

Fiat Chrysler LP.7N029

LP.7N029 Door Trim Panel Assembly Heat Age Exposure Test

Military Standard 202, method 107

Mil Std 202

Military Standard 810G, method 503

Mil Std 810

Military Standard 810G, method 509.5

Mil Std 810

Military Standard 883J, 1010.8, ver. A, B, C, D, F

Mil Std 883

Military Standard 883J, 1011.9, ver. A, B, C

Mil Std 883

NFPA 79:2015

NFPA 79

Nissan NES M0131

NES M0131 High Temp testing passenger parts

EV / WW

Nissan NES M0132

NES M0132 Thermal cycle test plastic parts, “NTC-1-5A”

WWH / EVH / Xceed / ENDH 

SAE J575 AUG2015

“J575”, “Dust exposure test”, “J575 4.12”

SEMI S2-0715

SEMI S2, SEMI S8, SEMI S14

VDA 276 VOC-1m3 Test method

VDA 276

Volkswagen PV 1200

VW PV1200

WWH / EVH / Xceed / ENDH 

Volkswagen PV 2005 Variant A

VW PV2005

WWH / EVH / Xceed / ENDH 

Volkswagen PV 2005 Variant B

VW PV2005

WWH / EVH / Xceed 

EUCAR Hazard Levels

EUCAR Hazard Levels

-ER

EN 60068-2-60

Corrosive Gas Testing, low corrosive gas concentrations, mixed gas test, low gas ppb concentration test,

EN 60068-2-42

Corrosive Gas Testing

EN 60068-2-43

Corrosive Gas Testing

EMC

EMC Electromagnetic Compatibility

VW 80000 LV 124 K15

Condensation Test

ENDH 

Condensation Test

Condensation Test

ENDH 

Daimler MBN LV 124-2 K15

Condensation Test

ENDH 

VW PV 1200 (10/2004)

VW PV 1200 (10/2004)

ENDH 

BMW PR 308.2 (04/2006)

BMW PR 308.2 (04/2006)

ENDH 

VW PV 1200 Variant A (09/2000)

VW PV 1200 Variant A (09/2000)

ENDH 

VW PV 2005 Variant A (09/2000)

VW PV 2005 Variant A (09/2000)

ENDH 

DIN 72300-4 and ISO 16750-4 5.4.2 Water Shock

Water Shock, air/ice water test, Thermal shock test cabinet for air/ice water tests, Splash water test

EN ISO 6988 (DIN 50 018)

SO2 gas dosing

DIN 50 014-5

Direct spraying of brine, automatic operation

VOLVO STD 1027, 1375

Direct spraying of brine, automatic operation

Salt Spray, SC-IU

VOLVO STD 1027, 14

Direct spraying of brine, automatic operation

Salt Spray, SC-IU

VOLVO VCS 1027, 149

Direct spraying of brine, automatic operation

Salt Spray, SC-IU

VOLVO STD 423-0014

Direct spraying of brine, automatic operation

Salt Spray, SC-IU

VOLVO VCS 1027, 1449

Direct spraying of brine, automatic operation

Salt Spray, SC-IU

Ford CETP: 00.00-L-467

Direct spraying of brine, automatic operation

Salt Spray, SC-IU

RENAULT D17 2028/–C (2007), Test ECC1

RENAULT D17 2028/–C (2007), Test ECC1

Salt Spray, SC-IU

DIN EN ISO 6270-2 test CH, AHT

Condensed water test

Ozone

Ozone test

IEC 68268, EN 60529 LC1

Dust

MIL-STD 810G, Method 510.5

Dust

DIN EN 60529 September 2000

Spray Water Testing, Spray Splash Water Test, IP Test, IPX1, IPX2, IPX3, IPX4, IPX5, IPX6, IPX6K, IPX9K

JIS D 0203-1994

JIS D 0203-1994

Weathering tests:

DIN EN ISO 4892-3, procedure A (lamp combination)
cycle number 3+4
DIN EN 12224
VDI 3958 page 12
DIN EN 1297
EOTA TR-010
NF T 30-049 *
NF P 84-402 *
Acid precipitations:
ADF (Acid Dew and Fog) VDI 3958 page 12) *1
AR (Acid Rain) VDI 3958, page 12
DIN 55663 draft

Weathering test chamber, ADF test, acid dew and fog text, AR test, acid rain test

Low-temperature tests
IEC 60068-2-1, Test A

High-temperature tests
IEC 60068-2-2, Test B
Alternating temperature tests
IEC 60068-2-14, Test Nb
Constant Climates

IEC 60068-2-67
IEC 60068-2-78
Solar simulation tests
MIL-STD-810 G, Meth. 505.5 Procedure II
DIN 75220
PV 1211
PR 306.4

Solar simulation test chamber

UV

EN 1539

EN 1539

DIN EN ISO 20857/2013, ISO 7, ISO 5

DIN EN ISO 20857/2013, ISO 7, ISO 5

DIN EN ISO 9227: 2012-09

DIN EN ISO 9227: 2012-09

DIN EN ISO 9227: 2015-09

DIN EN ISO 9227: 2015-09

DIN EN ISO 6270-2: 2005-09

Condensation Test

ASTM G 85, A2, A3, A5 
Nissan M 0158 CCT I;IV

Bosch N 42 AP 108 3.1, 3.2, 3.3
VW PV 1210
DIN EN ISO 60068-2-52 Severity 1…8
VW PV 3.15.3
Ford CETP 00.00-L-467
Renault D172028, ECC 134
GME 9540 P
SAE J 2334
GM 3172
Toyota TSH 1555 G, Meth. A,B,C
GMW 14872
Volvo STD 1027, 14,… 149, …1449
JASO M 610
Volvo STD 1027, 1375
Nissan M 0007 CCT I,II, IV
Volvo STD 423-0014

Corrosion Alternating Tests with controlled climate

Honda CCT 5100 Z-SGO-AOO
VDA 233-102
Hyundai/Kia MS 600-66 (CCT C)
Voest Alpine
KWT DC/PA PP PWT 3101
VW PV 1209
VDA 621-415 B

Corrosion Alternating Tests with controlled climate and freeze

DIN IEC 68-2-14 Nc (N42AP 221).

Air to liquid thermal shock test, Ice water shock test

DIN EN ISO 12460-3

DIN EN ISO 12460-3, CARB, FAPE, formaldEhyde test

EN 717-1
ASTM D 6007
VOC: ISO 16000-9

Formaldehyde test, emission test chamber

ISO 16000-9
ISO12219-4
VDA 276-2
ASTM D6007-02
PV 3943

Emission test chamber, Static tests without carrier gas exchange, dynamic  tests with carrier gas exchange

SHED, HC Emissions

SHED, HC Emissions

IEC-60068-2-14, Test Na², transfer time < 10 sec

MIL-STD-810 G, Method 503.5
MIL-STD-883 J, Method 1010.8 Variants A,B,C,D (D³ for 300l shock chamber), F
JEDEC standard JESD22-A106B

MIL STD 810G, 503.5, MIL-STD 883J, Method 1010.8 Variants A, B, C, D, D3, JESD22-A106B, Thermal Shock Test

ATEX Directive 2014/34/EU
ISO 16000-9 (April 2008)
ISO 10580 (October 2010)
EN 717-1 (January 2005), part 1
prEN 13419-1 (January 2003)
prEN 15052 (October 2004)
ISO/DIS 12219-4 (December 2011)
VDA 276-2 (December 2005)
PV 3943 (December 2000)
ASTM D 6330-98 (January 1999)
ASTM D 6007-02 (June 2002)
Cal Spec. 03150 (February 2010)
HJ 571-2010 (2010)
GEV test method (November 2001)
IOS-MAT-0010 (May 2007)”

ATEX, explosion protection

Emission test chamber

DIN EN 1539

Dryer for flammable substances, oven for flammable substances, dryer for combustible substances, oven for combustible substances

ATEX Oven

Explosion-Proof Drying Oven, ATEX oven

Test Standard

Test Category

Test Description

Temperature & Humidity

Weiss Technik Chamber Solution

ASTM D4322 / ISO 2233

Package testing of pharma/medical product

Condition 1 (cryogenic, special atmosphere)

-55 C., uncontrolled RH

ASTM D4322 / ISO 2233

Package testing of pharma/medical product

Condition 2 (preferred atmosphere

-35 C., uncontrolled RH

ISTA 2A, 3A

Package testing of pharma/medical product

Extreme cold

-29 C., uncontrolled RH

ASTM D4332 / ISO 2233 / ISTA 2A,3A

Package testing of pharma/medical product

Condition 3 (frozen food, special atmosphere), Severe
cold

-18 C., uncontrolled RH

ASTM D4332 / ISO 2233 / ISTA 2A,3A

Package testing of pharma/medical product

Condition 4 (refrigerated storage, special atmosphere)

5 C., uncontrolled RH

ASTM D4332 / ISO 2233 

Package testing of pharma/medical product

Condition 5 (preferred atmosphere)

20 C., 65% RH

ASTM D4332 / ISO 2233 

Package testing of pharma/medical product

Condition 6 (temperature high humidity, special
atmosphere)

20 C., 90% RH

ISO 2233 / ISTA 2A,3A

Package testing of pharma/medical product

Condition 7 (controlled conditions)

23 C., 50% RH

ASTM D4332 / ISO 2233 

Package testing of pharma/medical product

Condition 8 (preferred atmosphere)

30 C., 85% RH

ASTM D4332 / ISO 2233 

Package testing of pharma/medical product

Condition 9 (preferred atmosphere)

30 C., 90% RH

ISTA 2A, 3A

Package testing of pharma/medical product

Hot/humid then heat/moderate RH

38 C., 85% RH

ISTA 2A, 3A

Package testing of pharma/medical product

Hot/humid then heat/moderate RH

60 C., 30% RH

ASTM D4332 / ISO 2233

Package testing of pharma/medical product

Condition 10 (preferred atmosphere)

40 C., uncontrolled RH

ASTM D4332 / ISO 2233

Package testing of pharma/medical product

Condition 11 (tropical, special atmosphere)

40 C., 90% RH

ISTA 2A, 3A, 4AB

Package testing of pharma/medical product

Desert and Hot/dry

50 C., uncontrolled RH

50 C., 25% RH

ASTM D4332 / ISO 2233

Package testing of pharma/medical product

Condition 12 (preferred atmosphere)

55 C., 30% RH

ASTM D4332 / ISTA 2A, 3A

Package testing of pharma/medical product

Desert (special atmosphere) / Extreme heat, Dry

60 C., 15% RH

Pharma / Lab Event – L / ENDH

USP 670

Packaging development

Moisture adsorption at dry conditions

25 C., 40% RH

Pharma / Pharma-L / 
Lab Event – L / ENDH

USP 670

Packaging development

Moisture adsorption at humid conditions

25 C., 80% RH

Pharma / Pharma-L / 
Lab Event – L / ENDH

TAPPI T 402

Stability testing of pulp and paper product

Conditioning and Testing atmospheres

23 C., 50% RH

Pharma / Pharma-L / 
Lab Event – L / ENDH

ASAP test protocol

Accelerated pharma stability testing

Accelerated testing conditions, point 1

50 C., 75% RH

ASAP test protocol

Accelerated pharma stability testing

Accelerated testing conditions, point 2

60 C., 40% RH

Pharma / Lab Event – L / ENDH

ASAP test protocol

Accelerated pharma stability testing

Accelerated testing conditions, point 3

70 C., 5% RH

Pharma / Lab Event – L / ENDH

ASAP test protocol

Accelerated pharma stability testing

Accelerated testing conditions, point 4

70 C., 75% RH

Pharma / Lab Event – L / ENDH

ASAP test protocol

Accelerated pharma stability testing

Accelerated testing conditions, point 5

80 C., 40% RH

ICH Q1A

Standard pharma stability testing

Stability testing, long term storage

25 C., 60% RH

Pharma / Pharma-L / 
Lab Event – L / ENDH

ICH Q1A

Standard pharma stability testing

Stability testing, long term storage

30 C., 65% RH

Pharma / Pharma-L / 
Lab Event – L / ENDH

ICH Q1A

Standard pharma stability testing

Stability testing, intermediate term storage

30 C., 65% RH

Pharma / Pharma-L / 
Lab Event – L / ENDH

ICH Q1A

Standard pharma stability testing

Stability testing, intermediate term storage

30 C., 75% RH

Pharma / Pharma-L / 
Lab Event – L / ENDH

ICH Q1A

Standard pharma stability testing

Stability testing, accelerated storage

40 C., 75% RH

Pharma / Pharma-L / 
Lab Event – L / ENDH

ICH Q1A

Standard pharma stability testing

Stability testing, long term refrigerator storage

5 C., uncontrolled RH

ICH Q1A

Standard pharma stability testing

Stability testing, accelerated refrigerator storage

25 C., 60% RH

Pharma / Pharma-L / 
Lab Event – L / ENDH

ICH Q1A

Standard pharma stability testing

Stability testing, long term freezer storage

-20 C., uncontrolled RH

ICH Q1A

Standard pharma stability testing

Stability testing, long term semi-permeable container storage

25 C., 40% RH

Pharma / Pharma-L / 
Lab Event – L / ENDH

ICH Q1A

Standard pharma stability testing

Stability testing, long term semi-permeable container storage

30 C., 35% RH

Pharma / Pharma-L / 
Lab Event – L / ENDH

ICH Q1A

Standard pharma stability testing

Stability testing, intermediate semi-permeable container storage

30 C., 65% RH

Pharma / Pharma-L / 
Lab Event – L / ENDH

ICH Q1A

Standard pharma stability testing

Stability testing, accelerated semi-permeable container
storage

40 C., 25% RH

Pharma / Pharma-L / 
Lab Event – L / ENDH

ASTM D4169

Performance testing of shipping containers and systems

Environmental hazard testing per Assurance Level I

-54 to 71 C., uncontrolled RH

ASTM D4169

Performance testing of shipping containers and systems

Environmental hazard testing per Assurance Level II

0 to 71 C., uncontrolled RH

ASTM F1980

Accelerated aging of sterile barrier system for medical devices

Accelerated aging test

25 to 60 C., uncontrolled RH

ISO 11607

Packaging for terminally sterilized medical devices

Accelerated aging test

50 to 60 C., uncontrolled RH

International Federation of Societies of Cosmetic Chemists, IFSCC
Monograph #2: The Fundamentals of
Stability Testing

Standard cosmetic stability testing

Control Temperature

4 C., uncontrolled RH

International Federation of Societies of Cosmetic Chemists, IFSCC
Monograph #2: The Fundamentals of
Stability Testing

Standard cosmetic stability testing

Room Temperature

20-25 C., uncontrolled RH

International Federation of Societies of Cosmetic Chemists, IFSCC
Monograph #2: The Fundamentals of
Stability Testing

Standard cosmetic stability testing

Accelerated Testing

37 C., uncontrolled RH

International Federation of Societies of Cosmetic Chemists, IFSCC
Monograph #2: The Fundamentals of
Stability Testing

Standard cosmetic stability testing

Accelerated Testing

37 C., 80% RH

Pharma / Pharma-L / 
Lab Event – L / ENDH

International Federation of Societies of Cosmetic Chemists, IFSCC
Monograph #2: The Fundamentals of
Stability Testing

Standard cosmetic stability testing

Accelerated Testing

45 C., uncontrolled RH

Cosmetic Regulation in a Competitive Environment,
Chapter 11: Stability
Testing of Cosmetic Products

Standard cosmetic stability testing

Room Testing

24 to 25 C., uncontrolled RH

Cosmetic Regulation in a Competitive Environment,
Chapter 11: Stability
Testing of Cosmetic Products

Standard cosmetic stability testing

Accelerated Testing

37 to 50 C., uncontrolled RH

Cosmetic Regulation in a Competitive Environment,
Chapter 11: Stability
Testing of Cosmetic Products

Standard cosmetic stability testing

Freeze-thaw cycling

0 C. or -5 C., uncontrolled RH

Cosmetic Regulation in a Competitive Environment,
Chapter 11: Stability
Testing of Cosmetic Products

Standard cosmetic stability testing

Elevated Humidity

37 to 50 C., 80% RH

ICH Q1B

Standard cosmetic stability testing

Refrigerated conditions photostability testing, affects of light on product

5 C., unconrollted RH

ICH Q1B

Standard cosmetic stability testing

Stability conditions photostability testing, affects of light on product

25 to 40 C., 40 – 70% RH

Pharma / Pharma-L